Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Vasc Surg ; 71(5): 1538-1545, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31699510

RESUMO

OBJECTIVE: The majority of endovascular aneurysm repair procedures are performed through the common femoral artery (CFA). Arterial access is gained by surgical cutdown or percutaneous approach. The surgical approach has a relatively high local complication rate. We describe superficial femoral artery (SFA) access as an alternative to CFA exposure to minimize wound complications and to facilitate swift recovery. METHODS: A single-center, retrospective study of patients undergoing endovascular aneurysm repair between 2014 and 2016 was performed; 195 patients undergoing 215 procedures were included, 114 with CFA cutdown, 87 with SFA cutdown, and 14 with combined SFA and CFA procedures. Epidemiologic parameters, risk factors, procedural details, operative and postoperative complications, and time to discharge were assessed. Independent samples two-sided t-test and χ2 test were used to compare the SFA and CFA. A P value < .05 was considered statistically significant. A multivariate adjusted model confirmed the results. The proximal SFA is assessed by computed tomography angiography for patency and suitability. The minimal SFA diameter of 6 mm was determined for considering SFA access. Through a longitudinal incision at the upper thigh, the SFA is exposed and catheterized. Devices are inserted sheathless and replaced by small-diameter sheaths (14F-16F). Patients undergo peripheral vascular examination before and after the procedure. RESULTS: Age, sex, and risk factor distribution were similar in both groups. Aneurysm size and device diameters were also similar. There were 12.1% of cases that were not suitable for the SFA approach. Access-related bleeding (0.7% SFA, 7% CFA; P = .004), ischemia (0.7% SFA, 7.6% CFA; P = .002), and venous injury (0% SFA, 1.3% CFA; P = .102) were minimized with SFA exposure. This led to almost 50% decrease in patients requiring additional arterial reconstruction during the procedure (6.5% SFA, 12.8% CFA; P = .059). SFA cutdown was also associated with lower wound complication rate (infection, seroma, and hematoma; 13.2% SFA, 34.9% CFA; P = .000). Neuropathy (mostly sensory) was higher with SFA exposure (13.8% SFA, 5.2% CFA; P = .008). The patients' recovery was faster in the SFA group, resulting in 14.3% reduction of hospital stay after the procedure (P = .005). Secondary access-related procedures were also lower in the SFA group (2.2% SFA, 8.7% CFA; P = .045). CONCLUSIONS: The SFA approach is easier to perform and has a lower complication rate compared with the CFA approach. During the procedure, there is no dissection or damage to arterial branches, especially to the deep femoral artery. The SFA approach has a low complication rate and can be an alternative to percutaneous access when it is unsuitable.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Cateterismo Periférico , Procedimentos Endovasculares , Artéria Femoral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Cateterismo Periférico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Tempo de Internação , Masculino , Readmissão do Paciente , Complicações Pós-Operatórias/cirurgia , Punções , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Cicatrização
2.
J Endovasc Ther ; 26(5): 658-664, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31198085

RESUMO

Purpose: To describe a hybrid procedure that avoids cardiopulmonary bypass to treat patients with true ascending aortic aneurysms without a suitable proximal landing zone for endovascular repair. Material and Methods: Thirteen consecutive patients (mean age 75.9±6.5 years; 8 women) with true ascending aortic aneurysms were treated with the endovascular hybrid repair of true aortic aneurysms (EHTA) approach, which consists of a conventional sternotomy with double wrapping of the ascending aorta followed by staged stent-graft placement. Via sternotomy, a polypropylene mesh trimmed to downsize the aneurysm is placed around the dilated ascending aorta and sutured to the adventitia. A similarly trimmed polytetrafluoroethylene graft is placed loosely around the first wrap to avoid adhesions and secure the proximal landing zone. There is no need for cardiopulmonary bypass. A few days later, a standard thoracic stent-graft is deployed via either a transaxillary or transfemoral access; chimney or bypass grafts are used as needed to revascularize the supra-aortic vessels. Results: The ascending aortic diameter was reduced from a mean 5.7 cm (range 4.8-6.5) to 3.9 cm (range 3.2-4.3) after wrapping. The mean interval between surgery and stent-graft placement was 5 days. In this interval, 2 patients with significant reduction in the diameter of the ascending aorta elected to forego placement of a stent-graft. Of the 11 patients who underwent the full hybrid EHTA procedure, the ascending aortic stent-graft was combined with a chimney graft in the innominate artery in 4 cases. In 1 patient, a supra-aortic debranching procedure using a bifurcated Dacron graft to the innominate and left common carotid arteries was performed after wrapping with the polypropylene mesh. There was no mortality or neurological complication. A sternal wound infection required a prolonged hospital stay. At a mean follow-up of 13.8 months (range 3-24), there has been no death, type I endoleak, or sign of aneurysm enlargement on imaging. Conclusion: This technique permits complete endovascular exclusion of an ascending aortic aneurysm in a less invasive approach than standard open repair. Although this is only a small cohort of patients without long-term follow-up, it seems that this hybrid procedure is associated with low morbidity and mortality. It offers a beating-heart approach to treat true ascending aortic aneurysms in selected high-risk patients.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Esternotomia , Fatores de Tempo , Resultado do Tratamento
3.
Isr Med Assoc J ; 21(5): 322-325, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31140223

RESUMO

BACKGROUND: Access-site bleeding is a common complication of transfemoral transcatheter aortic valve implantation (TAVI). Percutaneous stent-graft implantation within the femoral artery may achieve hemostasis and avert the need for more invasive surgical vascular repair; however, failure to advance a guidewire antegradely via the injured vessel may preclude stent delivery. While retrograde stent-graft delivery from the distal vasculature may potentially enable percutaneous control of bleeding, this approach has not been reported. OBJECTIVES: To assess the feasibility of a retrograde approach for stent-graft implantation in the treatment of access-site bleeding following transfemoral TAVI. METHODS: A prospective TAVI registry was analyzed. Of 349 patients who underwent TAVI, transfemoral access was used in 332 (95%). Access-site injury requiring stent-graft implantation occurred in 56 (17%). In four patients (7%), antegrade wiring across the site of vascular injury was not possible and a retrograde approach for stent delivery was used. RESULTS: Distal vascular access was achieved via the superficial femoral or profunda artery. Retrograde advancement of a polymer-coated 0.035" wire to the abdominal aorta, followed by stent-graft delivery to the common femoral artery, achieved hemostasis in all cases. During a median (interquartile range) follow-up period of 198 (618) days (range 46-2455) there were no deaths and no patient required additional vascular interventions. CONCLUSIONS: A retrograde approach for stent-graft delivery is feasible and allows percutaneous treatment of a common femoral artery injury following TAVI in patients who are not suitable for the conventional antegrade approach.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Periférico , Artéria Femoral/cirurgia , Complicações Intraoperatórias , Hemorragia Pós-Operatória , Substituição da Valva Aórtica Transcateter , Lesões do Sistema Vascular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Estudos de Viabilidade , Feminino , Próteses Valvulares Cardíacas , Hemostasia Cirúrgica/métodos , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/terapia , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/terapia
4.
A A Pract ; 13(4): 151-154, 2019 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-30985316

RESUMO

We present a patient who was admitted for carotid endarterectomy due to tight carotid stenosis and recent amaurosis fugax. His medical history included significant coronary artery disease with stable angina pectoris, hypertension with wide pulse pressure, chronic renal failure, and anemia. During preparation for surgery, the patient developed type 2 myocardial infarction with prolonged chest pain, ST depressions on electrocardiogram, and significant troponin elevations. The patient posed a serious clinical dilemma whether to continue with surgery despite the type 2 myocardial infarction or postpone the surgery. We discuss the diagnostic tests and the decision-making processes that guided us in the preoperative period.


Assuntos
Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/métodos , Infarto do Miocárdio/diagnóstico por imagem , Idoso de 80 Anos ou mais , Estenose das Carótidas/complicações , Tomada de Decisão Clínica , Eletrocardiografia , Humanos , Masculino , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/metabolismo , Assistência Perioperatória , Resultado do Tratamento , Troponina/metabolismo
7.
Am J Cardiol ; 120(3): 456-460, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28583682

RESUMO

Vascular complications are common after transcatheter aortic valve replacement (TAVR) and are associated with increased morbidity and mortality. Stent graft implantation enables percutaneous treatment of access site bleeding; however, the efficacy and durability and of this approach are unknown. We studied the immediate outcome of stent graft implantation for control of access site bleeding and the need for repeat vascular interventions after stenting, in a cohort of consecutive patients with severe symptomatic aortic stenosis who underwent transfemoral TAVR. Predictors of access site complications requiring percutaneous or surgical vascular repair were identified. Transfemoral TAVR was performed in 194 patients. Access site complications requiring urgent vascular repair occurred in 34 patients (18%). Stent graft implantation was performed in 31 patients and vascular surgery in 3 patients. When patients who required surgical or percutaneous vascular repair were compared with those who did not, increased body mass index (30 ± 6 vs 28 ± 5, p = 0.035) and reduced activated clotting time (233 ± 47 vs 252 ± 47, p = 0.030) were the only predictors of need for vascular repair. Stenting achieved adequate hemostasis in all patients with a single minor vascular complication. During median follow-up of 797 days (interquartile range 585 to 1,173), no clinically significant vascular complications were detected after stenting. In conclusion, control of bleeding was achieved in all patients who underwent stent graft implantation for treatment of access site vascular complications after transfemoral TAVR. None of these patients needed further vascular interventions during follow-up.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Cateterismo Periférico/efeitos adversos , Artéria Femoral/cirurgia , Hemorragia Pós-Operatória/cirurgia , Stents , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Angiografia , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Humanos , Masculino , Hemorragia Pós-Operatória/diagnóstico , Hemorragia Pós-Operatória/etiologia , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
8.
Isr Med Assoc J ; 19(5): 289-292, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28513115

RESUMO

BACKGROUND: Stroke is a major cause of death in the western world, and carotid endarterectomy has been shown to be effective in treating both symptomatic and asymptomatic carotid stenosis. Carotid stenting is a relatively new form of treatment for carotid stenosis and few studies have looked specifically at asymptomatic patients. OBJECTIVES: To retrospectively examine short- and long-term results in the treatment of asymptomatic carotid artery stenosis with surgery or stenting. METHODS: We retrospectively collected data of all patients with asymptomatic carotid stenosis treated by carotid artery stenting or carotid endarterectomy in our department from 2006-2007. The primary endpoints were stroke, myocardial infarction, or death during the periprocedural period; or any ipsilateral stroke, restenosis, or death within 4 years after the procedure. RESULTS: The study comprised 409 patients who were treated by either stenting or surgery. There was a low morbidity rate in both treatment groups with no significant difference in morbidity or mortality between the treatment groups in both in the short-term as well as long-term. CONCLUSIONS: Both treatment methods have a low morbidity and mortality rate and should be considered for patients with few risk factors and a long life expectancy. Treatment method should be selected according to the patient's individual risk factors and imaging data.


Assuntos
Doenças Assintomáticas/terapia , Estenose das Carótidas/terapia , Endarterectomia das Carótidas , Stents , Artérias Carótidas , Estenose das Carótidas/mortalidade , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/mortalidade , Humanos , Infarto do Miocárdio/etiologia , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
10.
J Cardiovasc Surg (Torino) ; 58(6): 814-817, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27332677

RESUMO

BACKGROUND: For an asymptomatic patient with severe carotid stenosis the most important question is how to prevent an ischemic stroke. Carotid artery stenosis is the estimated cause of stroke in 8-20% of the cases. Today more than 50% of procedures for carotid stenosis are done on asymptomatic patients, but few of the randomized controlled trials comparing carotid endarterectomy and stenting examined specifically these patients. METHODS: All patients with severe (>70%) asymptomatic carotid artery stenosis seen in the Carmel medical center vascular clinic were prospectively screened and randomized 1:1 for carotid endarterectomy (CEA) or carotid stenting (CAS). Patients eligible for both procedures were enrolled. The primary objectives of the study were: 1) periprocedural complications - stroke (CVA), transient ischemic attack (TIA), myocardial infarction (MI), and death; 2) long-term results: mortality, prevention of ipsilateral stroke or TIA, and freedom from restenosis. RESULTS: One-hundred and thirty-six patients were treated with mean follow-up of 26 months. There was no difference in short and long term results between the two groups. Thirty day morbidity included: 1 CVA in each group with no MI. Long-term results included 4 deaths in each group; none from CVA. One TIA was noted after CAS, and 3 cases of restenosis were found in CEA and one in CAS. CONCLUSIONS: CAS is a maturing procedure and has improved significantly over the past several years. Future developments of stents and protection devices will achieve better perioperative results. This along with our excellent long term results will promote the use of stenting for suitable patients.


Assuntos
Estenose das Carótidas/terapia , Endarterectomia das Carótidas , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Doenças Assintomáticas , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/mortalidade , Intervalo Livre de Doença , Endarterectomia das Carótidas/efeitos adversos , Endarterectomia das Carótidas/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Ataque Isquêmico Transitório/etiologia , Israel , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Recidiva , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
11.
J Cardiovasc Surg (Torino) ; 57(3): 448-56, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27029672

RESUMO

Due to the shortage of commercially available off the shelf aortic arch grafts since the last years parallel grafts or chimney grafts have played an increasing role in the treatment of patients with aortic arch lesions. Although there are still issues with type endoleaks and gutters between the chimney graft and the aortic stent-graft remaining. We report our results with the Medtronic thoracic graft in combination with long self-expanding parallel grafts, to ensure an overlapping zone of more than 7 cm between the different grafts. Alternatively, sandwich configurations are used where a direct contact between the parallel graft and the aortic wall is avoided. We have placed a total of 65 parallel grafts into supra-aortic branches. In 21 cases chimney grafts were placed into the carotid artery, in most cases into the left common carotid artery. In 36 cases chimney grafts were placed into left subclavian artery. A maximum number of 4 parallel grafts were placed for total endovascular debranching. In addition, in 8 patients a parallel graft had to be placed into the innominate artery. There was a patency of 69% for all subclavian artery chimney grafts versus 73% for carotid artery parallel grafts. Of note is a stroke rate of 5.2% in all these cases. Only 2 of the patients with an occluded left subclavian artery chimney graft required a bypass procedure for arm claudication or ischemia. We had a primary type I endoleak rate of 28%. In almost 25% secondary interventions were required mainly to treat type I leaks, in those cases where the leak did not resolve spontaneously. The overall mortality rate was 3.5%. The results of parallel graft in the aortic arch are promising, but of major concern is still the high rate of type I endoleaks as well as the neurological complication rate, most probably due to catheter manipulation in patients with severe atherosclerotic arch lesions.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Doenças da Aorta/mortalidade , Prótese Vascular , Artérias Carótidas/cirurgia , Endoleak/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Stents , Acidente Vascular Cerebral/mortalidade , Resultado do Tratamento
12.
Injury ; 47(4): 811-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26948690

RESUMO

INTRODUCTION: As the Syrian civil war continues, medical care of the injured remains a priority for health facilities receiving casualties. Ziv Medical Centre, the closest hospital in Israel to the Syrian border, has received 500 casualties since February 2013. Seventeen of these patients had vascular injuries. This research reports the care of these seventeen patients and explores the challenges of treatment in patients with little antecedent clinical history and improvised initial care that may be complicated by delay to definitive care, sepsis and limb ischaemia. METHOD: Electronic and paper patient records were examined. Descriptive case series data are presented. RESULTS: Fifteen of the 17 patients were male. The mean age was 20 years (range 8-30 years). Causes of injury included gunshot wounds (4 patients), shrapnel (multi-fragment) injury (12 patients), and 1 patient was run over and dragged behind a car. The time from injury to transfer to definitive care ranged from 5h to 7 days (mean 43 h). All but one patient had associated non-vascular multiple-trauma. Thirteen patients presented with limb ischaemia. Four patients had arterio-venous fistula (AVF) or pseudoaneurysm. There were 5 upper and 10 lower limb major vascular injuries. Three patients had neck vessel injuries. All patients were investigated with CT angiography and underwent surgical or endovascular intervention. In 12 patients, 4 vessels were debrided and re-anastomosed and 13 vessels bypassed. Endovascular repair was performed in 4 patients. After initial revascularisation, 4 patients went on to amputation. There were no deaths. CONCLUSIONS: The injuries treated are heterogeneous, and reflect the range of high energy vascular trauma expected in conflict. The broad range of vascular solutions required to optimise outcomes, in particular, limb salvage, in turn, reflect the challenges of dealing with such injuries, especially within the context of sepsis, ischaemia and delay. As war continues, there is a pressing need to address the needs of patients with high energy injuries in austere environments where there is a dearth of health resources and where definitive care may be days away.


Assuntos
Amputação Cirúrgica/estatística & dados numéricos , Conflitos Armados , Salvamento de Membro/métodos , Medicina Militar , Traumatismo Múltiplo/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Lesões do Sistema Vascular/cirurgia , Adolescente , Adulto , Algoritmos , Criança , Procedimentos Clínicos , Feminino , Hospitais de Distrito , Humanos , Escala de Gravidade do Ferimento , Israel , Masculino , Traumatismo Múltiplo/fisiopatologia , Estudos Retrospectivos , Síria , Fatores de Tempo , Lesões do Sistema Vascular/fisiopatologia
13.
Free Radic Biol Med ; 76: 14-24, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25091896

RESUMO

Human carotid atherosclerotic plaque is in direct contact with circulatory blood components. Thus, plaque and blood components may affect each other. The current study presents the effects of plaque chloroform:methanol (C:M) extract on the HDL-associated enzyme paraoxnase 1 (PON1). This study is part of our investigation on the mutual effects of the interactions between atherosclerotic lesions and blood components. Recombinant PON1 (rePON1) was incubated with the human carotid plaques C:M extract and PON1 activities were analyzed. Lactonase and paraoxonase activities were elevated due to C:M treatment, by 140 and by 69%, respectively. Analytical chemistry analyses revealed specific phosphatidylcholines (PCs) as the plaque active components. Tryptophan fluorescence quenching assay, together with molecular docking, shows that PON1 activity is enhanced in correlation with the level of PC affinity to PON1. Molecular docking revealed that PCs interact specifically with H2-PON1 α-helix, which together with H1 enzyme α-helix links the protein to the HDL surface. These findings are supported by additional results from the PON1 ∆20 mutant that lack its H1-α-helix. Incubation of this mutant with the plaque C:M extract increased PON1 activity by only 20%, much less than the wild-type PON1 that elevated PON1 activity at the same concentration by as much as 95%. Furthermore, as much as the affinity of the enzyme to the PC was augmented, the ability of PON1 to bind to the HDL particle decreased. Finally, PON1 interaction with PC enhance its uptake into the macrophage cytoplasm. In conclusions, Specific lesion phosphatidylcholines (PCs) present in the human carotid plaque significantly enhance PON1 catalytic activities due to their interaction with the enzyme. Such a lesion׳s PC-PON1 interaction, in turn, competes with HDL PCs and enhances PON1 uptake by macrophage at the expense of PON1 binding to the HDL.


Assuntos
Arildialquilfosfatase/metabolismo , Artérias Carótidas/metabolismo , Lipoproteínas HDL/metabolismo , Macrófagos/metabolismo , Fosfatidilcolinas/metabolismo , Placa Aterosclerótica/metabolismo , Arildialquilfosfatase/química , Arildialquilfosfatase/genética , Artérias Carótidas/patologia , Cromatografia Líquida , Ácidos Graxos não Esterificados , Humanos , Macrófagos/patologia , Espectroscopia de Ressonância Magnética , Simulação de Acoplamento Molecular , Mutação/genética , Placa Aterosclerótica/patologia , Conformação Proteica , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Espectrometria de Massas em Tandem
14.
J Vasc Surg ; 59(6): 1562-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24613690

RESUMO

BACKGROUND: The sandwich technique is an endovascular off-the-shelf solution for patients with thoracoabdominal aortic aneurysms (TAAAs). In a sandwich configuration, the chimney stent runs in the middle of a space created by two or three aortic endografts. METHODS: All patients with TAAAs who were treated with the sandwich technique were included in the study. Self-expanding Viabahn grafts (W. L. Gore and Associates Inc, Flagstaff, Ariz) were used as parallel grafts in the renal arteries and visceral vessels. Caudad-facing chimney grafts were used for the visceral arteries and cephalad-facing periscope grafts for the renal arteries. RESULTS: During the study period, 32 patients with TAAAs were treated with sandwich grafts. Indication for the procedure in 43% was an acute onset of symptoms, including two patients with a rupture and a retroperitoneal hematoma. Three patients required an additional debranching procedure. A total of 104 chimney grafts were implanted. Two patients died postoperatively because of the operation. Major adverse events were recorded in five patients, including one patient with persistent paraplegia and two with permanent renal failure requiring dialysis. The incidence of chimney graft occlusion was higher in patients with three or four parallel grafts than in those with two chimney grafts only. Patients with chronic dissections had a 12-times higher incidence of chimney graft occlusion than aneurysm patients. The number of patients with type I or III endoleaks was higher in the group with three or four parallel grafts. CONCLUSIONS: The sandwich technique is an off-the-shelf endovascular alternative to treat patients with TAAAs in an emergent setting. The combination of chimney grafts with a periscope configuration enables a rapid endovascular aneurysm exclusion with acceptable midterm results.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Procedimentos Endovasculares/métodos , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
15.
J Lipids ; 2012: 762560, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22690338

RESUMO

Human carotid plaque components interact directly with circulating blood elements and thus they might affect each other. We determined plaque paraoxonase1 (PON1) hydrolytic-catalytic activity and compared plaque and blood levels of lipids, HDL, PON1, and HbA1c, as well as plaque-oxidized lipids in symptomatic and asymptomatic patients. Human carotid plaques were obtained from symptomatic and asymptomatic patients undergoing routine endarterectomy, and the lesions were ground and extracted for PON activity and lipid content determinations. Plaque PONs preserved paraoxonase, arylesterase, and lactonase activities. The PON1-specific inhibitor 2-hydroxyquinoline almost completely inhibited paraoxonase and lactonase activities, while only moderately inhibiting arylesterase activity. Oxysterol and triglyceride levels in plaques from symptomatic and asymptomatic patients did not differ significantly, but plaques from symptomatic patients had significantly higher (135%) linoleic acid hydroperoxide (LA-13OOH) levels. Their serum PON1 activity, cholesterol and triglyceride levels did not differ significantly, but symptomatic patients had significantly lower (28%) serum HDL levels and higher (18%) HbA1c levels. Thus LA-13OOH, a major atherogenic plaque element, showed significant negative correlations with serum PON1 activity and HDL levels, and a positive correlation with the prodiabetic atherogenic HbA1c. Plaque PON1 retains its activity and may decrease plaque atherogenicity by reducing specific oxidized lipids (e.g., LA-13OOH). The inverse correlation between plaque LA-13OOH level and serum HDL level and PON1 activity suggests a role for serum HDL and PON1 in LA-13OOH accumulation.

16.
Free Radic Biol Med ; 51(1): 234-42, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21530644

RESUMO

Human atherosclerotic lesions contain oxidized lipids that facilitate further oxidation of macrophages, LDLs, and oxidative stress (OS)-sensitive markers and inhibit the antiatherogenic enzyme paraoxonase 1 (PON1). Our aim was to isolate and identify the oxidizing agent in a human atherosclerotic lesion lipid extract (LLE) and to explore the mechanisms of oxidation and of PON1's effect on the oxidizing agent. Of the five main fractions separated from the LLE, only fraction 2 (F2) promoted macrophage reactive oxygen species (ROS) production via a mechanism requiring mitochondrial involvement, whereas the NADPH oxidase system was not involved. Incubation of F2 with PON1 abridged the former's peroxide value and reduced its capacity to oxidize OS markers. The active agent was a triglyceride composed of palmitic, oleic, and linoleic acids, with 0.3% of its linoleic moiety in oxidized form. Incubation of either F2 or an identical synthetic triglyceride with PON1 reduced their ability to oxidize macrophages, without affecting cellular accumulation of triglycerides. We conclude that macrophage ROS production by LLE occurs in the presence of a specific triglyceride and requires mitochondrial involvement. Lipid peroxide in the triglyceride can also facilitate lipid autoxidation. Both atherogenic pathways are suppressed by PON1, which acts as an antiatherogenic element.


Assuntos
Arteriosclerose/metabolismo , Arildialquilfosfatase/metabolismo , Doenças das Artérias Carótidas/metabolismo , Macrófagos/metabolismo , Triglicerídeos/metabolismo , Animais , Arildialquilfosfatase/antagonistas & inibidores , Humanos , Peróxidos Lipídicos/metabolismo , Espectroscopia de Ressonância Magnética , Camundongos , Mitocôndrias/metabolismo , NADPH Oxidases , Oxirredução , Estresse Oxidativo , Espécies Reativas de Oxigênio/metabolismo , Triglicerídeos/isolamento & purificação
17.
J Vasc Surg ; 53(5): 1431-7, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21276685

RESUMO

BACKGROUND: Endovascular treatment of the ascending aorta is particularly challenging because of the anatomic features of this aortic segment. Only patients without connective tissue disorders, clinically relevant aortic regurgitation or stenosis, or concomitant coronary artery disease can be considered for an endovascular procedure. We report our results in a series of patients with aneurysms or intramural hematoma, penetrating ulcers, or floating thrombus who were scheduled for stent grafting. METHODS: Only patients with ascending aortic pathology who were unfit for open surgery were treated with an endograft. When preoperative computed tomography imaging showed severe calcification of the aortic arch or thrombus lining, temporary clamping of the carotid arteries before wire and catheter introduction was performed. An extracorporeal bypass from the right groin to both carotid arteries with a roller pump was established and maintained during the procedure. The endograft was placed across the aortic valve into the left ventricle and deployed in a retrograde fashion. At the end of the procedure, ventriculography and, if necessary, coronary angiography was performed to rule out any damage to the left ventricle or the valve apparatus. RESULT: Eleven patients were scheduled for stent graft exclusion of ascending aortic pathology. In five cases because of discrepancies in length measurements and sizing, the thoracic endograft was cut to length intraoperatively after partial deployment on the operating table and reloaded to avoid covering of the innominate artery. The mean length of the ascending aorta covered was longer in aneurysm patients than in those with dissection. An 81-year-old patient presented with a type Ia leak. The distal landing zone in one patient was enlarged by debranching. One patient died after wire perforation of the left ventricle, and one patient sustained a cerebral stroke. Combined morbidity and mortality was 18%, and the technical success rate was 91%. CONCLUSIONS: Stent grafting of the ascending aorta is technically feasible but should be reserved for selected high-risk patients only, preferably in centers where vascular specialists cooperate closely with interventional cardiologists. Cardiac surgery with cardiopulmonary bypass is still the gold standard to treat ascending aortic aneurysms. Stent graft exclusion of more advanced and complex ascending aortic pathology should be performed only in centers with the necessary experience in transvalvular cardiac procedures.


Assuntos
Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Seleção de Pacientes , Desenho de Prótese , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Free Radic Biol Med ; 50(1): 148-56, 2011 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21044882

RESUMO

Paraoxonase 1 (PON1) is an HDL-associated lactonase with antiatherogenic properties. These include dampening the oxidation properties of human carotid lesion lipid extract (LLE), which in turn inactivates the enzyme. The aims of this study were to identify the PON1 inhibitor in LLE and explore the mechanism of inhibition. LLE inhibited both recombinant PON1 and HDL-PON1 lactonase activity in a dose- and time-dependent manner. Addition of antioxidants or electrophiles to LLE did not prevent PON1 inhibition. LLE was unable to inhibit a PON1 mutant lacking Cys284, whereas it did inhibit all other PON1 mutants tested. The inhibitor in the LLE was identified as linoleic acid hydroperoxide (LA-OOH) and inhibition was specific to this hydroperoxide. During its inhibition, PON1 acted like a peroxidase enzyme, reducing LA-OOH to LA-hydroxide via its Cys284. A similar reaction occurred with external thiols, such as DDT or cysteine, which also prevented PON1 inhibition and restored enzyme activity after inhibition. Thus, the antiatherogenic properties of HDL could be, at least in part, related to the sulfhydryl-reducing characteristics of its associated PON1, which are further protected and recycled by the sulfhydryl amino acid cysteine.


Assuntos
Arildialquilfosfatase/antagonistas & inibidores , Lesões das Artérias Carótidas/patologia , Cisteína/metabolismo , Ácidos Linoleicos/farmacologia , Peróxidos Lipídicos/farmacologia , Extratos de Tecidos/farmacologia , Animais , Arildialquilfosfatase/química , Arildialquilfosfatase/genética , Arildialquilfosfatase/metabolismo , Células CHO , Lesões das Artérias Carótidas/metabolismo , Domínio Catalítico/efeitos dos fármacos , Domínio Catalítico/genética , Cricetinae , Cricetulus , Cisteína/genética , Inibidores Enzimáticos/farmacologia , Humanos , Ácidos Linoleicos/metabolismo , Peróxidos Lipídicos/metabolismo , Lipoproteínas HDL/metabolismo , Lipoproteínas HDL/farmacologia , Proteínas Mutantes/química , Proteínas Mutantes/genética , Proteínas Mutantes/metabolismo , Compostos de Sulfidrila/metabolismo , Reagentes de Sulfidrila/farmacologia , Extratos de Tecidos/metabolismo
19.
Harefuah ; 149(12): 784-8, 811, 2010 Dec.
Artigo em Hebraico | MEDLINE | ID: mdl-21916102

RESUMO

Critical limb ischemia (CLI) is the most severe manifestation of peripheral artery occlusive disease. Without timely diagnosis and revascularization, patients with CLI are at risk of devastating complications including loss of limb and life. Therapeutic goals in treating patients with CLI include reducing cardiovascular risk factors, relieving ischemic pain, heating ulcers, preventing major amputation, improving quality of life and increasing survival. These aims may be achieved through medical therapy, revascularization or amputation. The past decade has seen substantial growth in endovascular therapies and options now exist for treating long segment occlusive disease, but surgical bypass may still yield more durable results. Patients who are younger, more active, and at low risk for surgery, may have better outcomes undergoing an operation. This is also indicated for endovascular failures, which may include technical failures or late occlusions after stents or other procedures. In contrast, frail patients with a limited life expectancy may experience better outcomes with endovascular therapy. For patients who are non-ambulatory, demented, or unfit to undergo revascularization, an amputation should be considered.


Assuntos
Arteriopatias Oclusivas/complicações , Isquemia/etiologia , Doença Arterial Periférica/complicações , Fatores Etários , Amputação Cirúrgica/métodos , Extremidades/irrigação sanguínea , Humanos , Isquemia/diagnóstico , Isquemia/terapia , Salvamento de Membro/métodos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...